Stateful Functions Reference

Complete reference for prev(), ema(), pid(), and delay() - the four stateful functions available in derived generator expressions.

Why this matters

Four functions turn a row-by-row data generator into a dynamic system simulator. prev() gives you memory (tanks fill up, inventories accumulate). ema() gives you smoothing (noisy sensors become clean signals). pid() gives you feedback control (outputs adjust to hit targets). delay() gives you transport lag (pipeline delays, conveyor times). Without these, you get snapshots. With them, you get time series that behave like real processes - and they persist state across pipeline runs.


Overview

Stateful functions remember values between rows for each entity independently. They are used inside derived column expressions and enable:

  • Integration / accumulation — running totals, level tracking, inventory counts
  • Smoothing — filtering noisy sensor readings into clean signals
  • Feedback control — PID controllers that adjust outputs to hit targets

Key behavior:

  • State is tracked per entity. If you have 5 sensors, each sensor has its own independent state.
  • State flows forward through rows — each row can see the previous row's value, but not future rows.
  • State can be persisted between pipeline runs with incremental.mode: stateful (see Incremental State Persistence).

All stateful functions are used inside derived generator expressions:

- name: my_column
  data_type: float
  generator:
    type: derived
    expression: "prev('my_column', 0) + new_value"

prev(column, default) — Previous Row Value

Full signature: prev('column_name', default_value)

What it does: Returns the value of column_name from the previous row for the same entity. On the first row, returns default_value.

Parameters

Parameter Type Required Description
column string Yes Column name to look back at (must be quoted)
default any Yes Value to use for the first row

Use Cases (General)

  • Running totals: prev('total', 0) + new_value
  • Level tracking: prev('level', 100) + inflow - outflow
  • First-order response: prev('temp', 25) + 0.1 * (target - prev('temp', 25))
  • Cumulative counts: prev('count', 0) + 1

Use Cases (Operations / Manufacturing)

  • Tank level integration — track fill level from inflow and outflow rates
  • Inventory tracking — running stock balance from receipts and issues
  • Equipment runtime hours — accumulate operating time per asset
  • Batch progress tracking — cumulative weight or volume processed

Example 1: Simple Running Total

Accumulate a counter that increments by 1 each row:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  - name: row_count
    data_type: int
    generator:
      type: derived
      expression: "prev('row_count', 0) + 1"

Row-by-row: 1, 2, 3, 4, 5, ... — each row adds 1 to the previous value.

Example 2: Tank Level with Inflow / Outflow

Track a tank's fill level as material flows in and drains out:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Inflow varies between 2-8 m³/hr
  - name: inflow_m3_hr
    data_type: float
    generator:
      type: random_walk
      start: 5.0
      min: 2.0
      max: 8.0

  # Outflow varies between 3-7 m³/hr
  - name: outflow_m3_hr
    data_type: float
    generator:
      type: random_walk
      start: 5.0
      min: 3.0
      max: 7.0

  # Tank level (m³) — integrates inflow minus outflow
  # Timestep = 5 min = 5/60 hours
  - name: level_m3
    data_type: float
    generator:
      type: derived
      expression: "max(0, min(100, prev('level_m3', 50.0) + (inflow_m3_hr - outflow_m3_hr) * (5/60)))"

How it works:

  • prev('level_m3', 50.0) — starts at 50 m³, then uses last row's level
  • (inflow - outflow) * (5/60) — net volume change over 5 minutes
  • max(0, min(100, ...)) — clamps to physical tank limits (0–100 m³)

Example 3: First-Order Lag Response

Simulate a system that gradually responds to a changing input (e.g., a room heating up toward a thermostat setting):

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Target temperature wanders between 20-30°C
  - name: target_temp_c
    data_type: float
    generator:
      type: random_walk
      start: 25.0
      min: 20.0
      max: 30.0

  # Actual temperature chases the target with a lag
  # Gain = dt/tau = 60/300 = 0.2 (20% correction per timestep)
  - name: actual_temp_c
    data_type: float
    generator:
      type: derived
      expression: "prev('actual_temp_c', 25.0) + 0.2 * (target_temp_c - prev('actual_temp_c', 25.0))"

How it works:

  • Each row, the actual temperature moves 20% of the way toward the target
  • A gain of 0.2 means dt/τ = 60s / 300s — a 5-minute time constant with 1-minute steps
  • Lower gain → slower response; higher gain → faster response

ema(column, alpha, default) — Exponential Moving Average

Full signature: ema('column_name', alpha, default_value)

What it does: Applies exponential smoothing to a noisy signal. Each output value blends the current reading with the previous smoothed value:

smoothed = alpha × current + (1 - alpha) × previous_smoothed

Parameters

Parameter Type Required Description
column string Yes Column to smooth (must be quoted)
alpha float Yes Smoothing factor (0.0–1.0)
default any Yes Initial smoothed value

Alpha Guide

Alpha Smoothing History Weight Best For
0.1 Heavy 90% history Slow sensors, long-term averaging
0.3 Moderate-heavy 70% history General-purpose filtering
0.5 Moderate 50/50 Balanced noise reduction
0.7 Moderate-light 30% history Responsive filtering
0.9 Light 10% history Fast response, minimal smoothing

Rule of thumb: Lower alpha = smoother output but slower to react. Higher alpha = noisier output but faster to react.

What alpha actually looks like in the output

Imagine a raw temperature signal bouncing between 70 and 80 degrees C, averaging around 75:

  • alpha = 0.1: The smoothed signal barely moves. It drifts slowly between 73-77, ignoring most of the bouncing. Great for filtering out noise, but it reacts very slowly to real changes.
  • alpha = 0.3: The smoothed signal follows the general trend but flattens out the spikes. Moves between 72-78. A good default for most sensor filtering.
  • alpha = 0.5: Half current reading, half history. The smoothed signal still tracks the raw signal but with softer edges. You can see the pattern but not the noise.
  • alpha = 0.9: Almost no smoothing. The output looks nearly identical to the raw signal, just slightly less jagged. Only useful when you want minimal filtering.

Bottom line: Start at 0.2-0.3 for most sensor filtering. Only go higher if you need fast reaction to real changes and can tolerate more noise in the output.

Example 1: Smoothing Noisy Temperature Readings

A thermocouple reports noisy readings. Use EMA to get a clean signal:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Raw thermocouple reading (noisy)
  - name: raw_temp_c
    data_type: float
    generator:
      type: random_walk
      start: 75.0
      min: 60.0
      max: 90.0

  # Smoothed temperature — filters out noise
  - name: smooth_temp_c
    data_type: float
    generator:
      type: derived
      expression: "ema('raw_temp_c', 0.2, 75.0)"

Result: smooth_temp_c tracks the trend of raw_temp_c but ignores short-term noise spikes. With alpha=0.2, each output is 20% current reading + 80% previous smoothed value.

Example 2: Filtering Production Rate Measurements

A production line's output rate (units/hour) fluctuates due to measurement noise:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Raw production rate (noisy)
  - name: raw_rate_uph
    data_type: float
    generator:
      type: random_walk
      start: 500.0
      min: 400.0
      max: 600.0

  # Smoothed rate for reporting
  - name: smooth_rate_uph
    data_type: float
    generator:
      type: derived
      expression: "ema('raw_rate_uph', 0.3, 500.0)"

  # Deviation from smoothed rate (quality signal)
  - name: rate_deviation
    data_type: float
    generator:
      type: derived
      expression: "raw_rate_uph - smooth_rate_uph"

Bonus: The rate_deviation column shows how far the raw reading is from the smoothed trend — useful for detecting real process changes vs. noise.


pid(pv, sp, Kp, Ki, Kd, dt, ...) — PID Controller

Full signature:

pid(pv=column, sp=column_or_value, Kp=float, Ki=float, Kd=float, dt=float,
    output_min=float, output_max=float, anti_windup=bool)

What it does: Calculates a control output that drives a process variable (pv) toward a setpoint (sp). It uses three terms based on the error (sp - pv):

  • P (Proportional): Reacts to current error — bigger error → bigger correction
  • I (Integral): Reacts to accumulated error — eliminates persistent offset over time
  • D (Derivative): Reacts to rate of change of error — dampens oscillations

The controller maintains integral and derivative state per entity across rows.

Parameters

Parameter Type Required Default Description
pv column ref Yes Process variable (the measurement)
sp column ref or float Yes Setpoint (the target value)
Kp float Yes Proportional gain
Ki float No 0.0 Integral gain
Kd float No 0.0 Derivative gain
dt float Yes Timestep in seconds
output_min float No 0 Minimum output value
output_max float No 100 Maximum output value
anti_windup bool No True Prevent integral windup when output saturates

The #2 PID mistake: wrong sign (direct vs reverse acting)

Odibi's pid() calculates error as setpoint - process_variable. This means:

  • When the process variable is above setpoint, error is negative
  • When the process variable is below setpoint, error is positive

For cooling controllers (more output = lower temperature), you need negative gains. Otherwise the PID output goes to zero exactly when you need maximum cooling:

Controller type When PV > SP, I need... Gains should be...
Cooling (valve, fan, vent) More output (more cooling) Negative Kp, Ki, Kd
Heating (heater, steam) Less output (less heating) Positive Kp, Ki, Kd
Pump draining a tank More output (more pumping) Negative Kp, Ki, Kd
Fill valve into a tank Less output (less filling) Positive Kp, Ki, Kd

The rule: If more output should DECREASE the process variable, use negative gains. If more output should INCREASE the process variable, use positive gains.

The #1 PID mistake: wrong dt

The dt parameter must match your simulation's scope.timestep in seconds:

scope.timestep dt value
1m 60
5m 300
1h 3600
10s 10

If your timestep is 5m but you set dt=60, the PID thinks each step is 1 minute and will over-correct by 5x. If you set dt=5, it thinks each step is 5 seconds and will barely respond. Always convert your timestep to seconds.

New to PID? Start here

Think of a PID controller as a thermostat with three knobs. The P/I/D terms above describe the math - here's what they mean in practice:

  • Kp too low? The process barely responds. Temperature sits above setpoint and nothing happens.
  • Kp too high? The process overshoots and oscillates - valve slams open, then shut, then open.
  • Ki too low (or zero)? The process gets close to setpoint but never quite reaches it. There's always a small offset.
  • Ki too high? The process overshoots badly and takes a long time to settle. The integral "winds up" from accumulated error.
  • Kd useful? Only when you see oscillation that P and I alone can't fix. Skip it for noisy measurements - it amplifies noise.

Start with this recipe:

  1. Set Ki=0, Kd=0. Increase Kp until the process responds without wild oscillation.
  2. Add a small Ki (try Kp / 10). This eliminates any remaining offset from setpoint.
  3. Only add Kd if the process oscillates. Try Kp / 4. Skip it entirely for noisy measurements.

Most simulations work fine with just P and I (set Kd=0).

Practical Tuning Guide

You don't need control theory to tune a PID. Follow these steps:

Step 1 — Start with P-only:

Set Kp to a small value (e.g., 1.0), Ki=0, Kd=0. Run the simulation.

  • If the output barely moves → increase Kp
  • If the output oscillates wildly → decrease Kp
  • If it settles near (but not exactly at) the target → that's normal, move to Step 2

Step 2 — Add I to eliminate offset:

Set Ki = Kp / 10 (start conservative). The integral term slowly nudges the output until the error is zero.

  • If it oscillates more → reduce Ki
  • If the offset goes away but takes too long → increase Ki

Step 3 — Add D (optional) to dampen oscillations:

Set Kd = Kp / 4. The derivative term resists rapid changes, smoothing out oscillations.

  • Only needed if Steps 1-2 still oscillate
  • Skip D for noisy measurements (it amplifies noise)

Example 1: Temperature Control with Cooling Valve

A cooling valve controls the temperature of a vessel. The PID adjusts valve position (0–100%) to hit the temperature setpoint:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Temperature setpoint (target)
  - name: temp_setpoint_c
    data_type: float
    generator:
      type: constant
      value: 75.0

  # Vessel temperature — responds to cooling valve (first-order lag)
  # Process gain: valve% → temperature change
  - name: vessel_temp_c
    data_type: float
    generator:
      type: derived
      expression: "prev('vessel_temp_c', 80.0) + 0.05 * (90.0 - prev('cooling_valve_pct', 50) * 0.3 - prev('vessel_temp_c', 80.0))"
      # 0.05 = dt/tau, 90.0 = heat source, 0.3 = cooling gain per % valve

  # PID controller output → cooling valve position
  - name: cooling_valve_pct
    data_type: float
    generator:
      type: derived
      expression: "pid(pv=vessel_temp_c, sp=temp_setpoint_c, Kp=-2.0, Ki=-0.1, Kd=-0.5, dt=60, output_min=0, output_max=100)"

What happens:

  1. Vessel starts at 80°C (above 75°C setpoint)
  2. PID detects temp above setpoint - increases cooling output (reverse-acting)
  3. Temperature drops toward 75°C
  4. Integral term eliminates any remaining offset
  5. Derivative term prevents overshoot

Example 2: Level Control with Pump Speed

A pump drains a tank to maintain a target level. The PID adjusts pump speed (0–100%) based on the current level:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Level setpoint (target)
  - name: level_setpoint_m3
    data_type: float
    generator:
      type: constant
      value: 50.0

  # Inflow disturbance — varies unpredictably
  - name: inflow_m3_hr
    data_type: float
    generator:
      type: random_walk
      start: 10.0
      min: 5.0
      max: 15.0

  # Tank level — integrates inflow minus pump outflow
  # Pump outflow = pump_speed_pct/100 * max_pump_rate(20 m³/hr)
  - name: tank_level_m3
    data_type: float
    generator:
      type: derived
      expression: "max(0, min(100, prev('tank_level_m3', 50.0) + (inflow_m3_hr - prev('pump_speed_pct', 50) / 100 * 20) * (5/60)))"

  # PID controller → pump speed
  - name: pump_speed_pct
    data_type: float
    generator:
      type: derived
      expression: "pid(pv=tank_level_m3, sp=level_setpoint_m3, Kp=-3.0, Ki=-0.2, Kd=0.0, dt=300, output_min=0, output_max=100)"

Why Kd=0 here: Level measurements are often noisy, and derivative action amplifies noise. For level control, PI (without D) is the standard approach.


delay(column, steps, default) — Transport Delay

Full signature: delay('column_name', steps, default_value)

What it does: Returns the value of column_name from steps rows ago for the same entity. Maintains an internal ring buffer of past values. During the first steps rows (before the buffer is full), returns default_value.

Parameters

Parameter Type Required Description
column string Yes Column name to delay (must be quoted)
steps int Yes Number of timesteps to look back (must be ≥ 1)
default any Yes Value to return during the initial fill period

Use Cases (General)

  • Pipeline transport: delay('pump_flow', 10, 50.0) — flow arrives at the other end 10 steps later
  • Conveyor belt: delay('weight_at_entry', 20, 0.0) — weight at exit = weight at entry, 20 steps ago
  • Batch queue: delay('job_submitted', 5, 0) — result available 5 steps after submission
  • Measurement lag: delay('lab_sample', 30, 0.0) — lab result arrives 30 minutes after sample taken

Use Cases (Operations / Manufacturing)

  • Pipeline transport delay — fluid takes time to travel through a pipe
  • Conveyor belt — material placed at one end arrives at the other end after a fixed time
  • Sample analysis turnaround — take a sample now, get results N minutes later
  • Oven/kiln transit time — product enters, exits after a fixed residence time
  • Paint drying / curing — apply coating, inspect after fixed drying time

Steps Guide

steps At 1-min timestep At 5-min timestep Feels like
1 1 minute 5 minutes Barely noticeable lag
5 5 minutes 25 minutes Short pipeline, nearby conveyor
10 10 minutes 50 minutes Medium pipeline, process queue
30 30 minutes 2.5 hours Long pipeline, lab analysis
60 1 hour 5 hours Cross-facility transport

How to calculate steps from physical delay:

steps = physical_delay_time / scope.timestep

Example: 500m pipe, flow velocity 1 m/s → transit = 500s ≈ 8.3 min
  At timestep "1m": steps = 8 (round to nearest integer)
  At timestep "5m": steps = 2

What delay() actually looks like in the output

Imagine pump flow bouncing between 8 and 12 m³/hr. With delay('pump_flow', 10, 10.0) at a 1-minute timestep:

  • First 10 rows: Delivery flow sits flat at 10.0 (the default). The pump is running, but nothing has arrived yet.
  • From row 11 onwards: Delivery flow starts bouncing between 8 and 12 — but it's showing what the pump was doing 10 minutes ago. If you overlay the two signals on a chart, the delivery trace is an exact copy of the pump trace, just shifted 10 steps to the right.
  • If the pump stops at row 50: Delivery flow keeps going for 10 more rows (rows 50-60), showing what was already in the pipe. Then it drops to whatever the pump was at row 50.

Bottom line: The output is a time-shifted photocopy of the input. No smoothing, no lag curve — just a pure shift. Combine with first-order dynamics if you want a more gradual arrival.

Example 1: Pipeline Transport Delay

A pump station sends flow through a 500m pipe. At the delivery point, flow appears 10 minutes later:

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # Pump output at the source
  - name: pump_flow_m3_hr
    data_type: float
    generator:
      type: random_walk
      start: 10.0
      min: 5.0
      max: 15.0

  # Flow at the delivery point — delayed by 10 timesteps
  - name: delivery_flow_m3_hr
    data_type: float
    generator:
      type: derived
      expression: "delay('pump_flow_m3_hr', 10, 10.0)"

How it works:

  • For the first 10 rows, delivery_flow_m3_hr returns the default (10.0)
  • From row 11 onwards, it returns whatever pump_flow_m3_hr was 10 rows ago
  • If pump flow changes at row 20, delivery flow changes at row 30

Row-by-row (simplified, 3-step delay for clarity):

With delay('pump_flow', 3, 10.0):

Row pump_flow delay() returns Why
1 8.5 10.0 Default — only 1 value stored, need 4
2 11.2 10.0 Default — 2 values stored
3 9.8 10.0 Default — 3 values stored
4 12.1 8.5 Buffer full — returns row 1's value
5 7.9 11.2 Returns row 2's value
6 10.3 9.8 Returns row 3's value

After the buffer fills (row 4 onwards), every output is exactly the input from 3 steps ago.

Example 2: Dead Time + First-Order Response

Real transport delays are often followed by first-order dynamics (the pipe has some mixing). Combine delay() with prev():

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  - name: input_signal
    data_type: float
    generator:
      type: random_walk
      start: 50.0
      min: 20.0
      max: 80.0

  # Pure delay
  - name: delayed_input
    data_type: float
    generator:
      type: derived
      expression: "delay('input_signal', 5, 50.0)"

  # First-order response to the delayed signal
  - name: output_signal
    data_type: float
    generator:
      type: derived
      expression: "prev('output_signal', 50.0) + 0.15 * (delayed_input - prev('output_signal', 50.0))"

Result: Output is flat for 5 steps (dead time), then gradually approaches the delayed input (first-order dynamics).

delay() vs prev()

Function Looks Back State Best For
prev() Exactly 1 row Single value Dynamic state (integrators, first-order, feedback)
delay() N rows Ring buffer of N+1 values Transport delays (fixed time shift)

delay('col', 1, default) produces the same result as prev('col', default).


Combining Stateful Functions

The real power emerges when you use all four together. Here's a complete example simulating a controlled process with noisy measurements:

scope:
  start_time: "2026-01-01T00:00:00Z"
  timestep: "1m"
  row_count: 120
  seed: 42

entities:
  names: [reactor_01]

columns:
  - name: timestamp
    data_type: timestamp
    generator:
      type: timestamp

  # --- Setpoint ---
  - name: temp_setpoint_c
    data_type: float
    generator:
      type: constant
      value: 80.0

  # --- Noisy sensor reading (raw measurement) ---
  - name: raw_temp_c
    data_type: float
    generator:
      type: derived
      expression: "prev('actual_temp_c', 80.0) + (random() - 0.5) * 4"
      # Actual temp + noise band of ±2°C

  # --- Smoothed measurement (EMA filter) ---
  - name: filtered_temp_c
    data_type: float
    generator:
      type: derived
      expression: "ema('raw_temp_c', 0.3, 80.0)"

  # --- PID controller (acts on filtered measurement) ---
  - name: cooling_pct
    data_type: float
    generator:
      type: derived
      expression: "pid(pv=filtered_temp_c, sp=temp_setpoint_c, Kp=-2.0, Ki=-0.1, Kd=-0.5, dt=60, output_min=0, output_max=100)"

  # --- Actual process temperature (first-order response to cooling) ---
  - name: actual_temp_c
    data_type: float
    generator:
      type: derived
      expression: "prev('actual_temp_c', 85.0) + 0.05 * (95.0 - prev('cooling_pct', 50) * 0.3 - prev('actual_temp_c', 85.0))"
      # Starts above setpoint; 95.0 = heat source equilibrium without cooling

What's happening:

Column Function Role
raw_temp_c prev() Adds noise to the actual temperature
filtered_temp_c ema() Smooths noisy reading for the controller
cooling_pct pid() Calculates valve position from filtered temp
actual_temp_c prev() Process dynamics — responds to cooling valve

Flow: actual temp → noisy sensor → EMA filter → PID controller → cooling valve → actual temp (loop)


Incremental State Persistence

When using incremental.mode: stateful, all stateful functions preserve their internal state between pipeline runs:

Function What's Preserved
prev() Last value per entity
ema() Last smoothed value per entity
pid() Integral sum and last error per entity
delay() Ring buffer of last N values per entity
random_walk Last walk value per entity

What this means: Run 2 picks up exactly where Run 1 left off — no discontinuities, no resets.

read:
  connection: null
  format: simulation
  options:
    simulation:
      scope:
        start_time: "2026-01-01T00:00:00Z"
        timestep: "1m"
        row_count: 60    # 1 hour per run
        seed: 42
      columns:
        - name: level_m3
          data_type: float
          generator:
            type: derived
            expression: "prev('level_m3', 50.0) + inflow - outflow"
  incremental:
    mode: stateful
    column: timestamp
Run 1: level starts at 50.0, ends at 63.2  →  state saved
Run 2: level starts at 63.2, ends at 58.7  →  state saved
Run 3: level starts at 58.7, ...            →  continuous

Without stateful mode, each run would restart prev('level_m3', 50.0) from 50.0, creating a jump.

See Stateful Incremental Loading for full configuration details.


Tips and Pitfalls

✅ Do

  • Quote column names in prev() and delay(): prev('level', 0) ✅ — delay('flow', 5, 0)
  • Define columns in dependency order: If column B uses prev('A', 0), define A before B (or use self-reference like prev('B', 0) within B's own expression)
  • Match dt to your actual timestep: If scope.timestep: "5m", use dt=300 (5 × 60 seconds) in pid()
  • Use anti_windup=True (the default) to prevent integral windup when the PID output hits min/max limits
  • Clamp integrated values: Use max(0, min(100, ...)) to keep levels, percentages, etc. within physical bounds
  • Choose a sensible default for delay(): The default is returned during the first N rows while the buffer fills. Use a realistic steady-state value (e.g., delay('flow', 10, 10.0) if flow is normally around 10)
  • Use delay() for transport, prev() for dynamics: delay() gives a pure time shift (ring buffer). prev() gives single-step memory for feedback and integration. Don't use chains of prev() columns when delay() does the job in one call

❌ Don't

  • Unquoted column names: prev(level, 0) ❌ or delay(flow, 5, 0) ❌ — will be interpreted as a variable, not a column name
  • Circular dependencies: Column A depends on current B, and B depends on current A. Use prev() to break the cycle:
    # ❌ Circular
    - name: level
      expression: "prev('level', 5) + flow_in - flow_out"
    - name: flow_out
      expression: "level * 0.1"        # Uses CURRENT level → circular
    
    # ✅ Fixed
    - name: level
      expression: "prev('level', 5) + flow_in - flow_out"
    - name: flow_out
      expression: "prev('level', 5) * 0.1"  # Uses PREVIOUS level → OK
    
  • Mismatched dt: If your timestep is 5 minutes but you set dt=60 (1 minute), the PID will over-correct by 5×
  • Derivative on noisy signals: If your measurement is noisy, set Kd=0 or apply ema() first — derivative amplifies noise