Seborg Textbook → Odibi Simulation Mapping

From Theory to Realistic Plant Data: A Beginner's Guide


About This Guide

This guide maps Process Dynamics and Control (Seborg et al., 3rd ed.) to practical data simulation in Odibi. If you're a chemical engineer trying to remember how to translate textbook equations into realistic plant data, this is your companion.

Who this is for: - ChemEs in operations/analytics who want to refresh process control concepts - Data engineers learning process industries - Anyone building demos that stand out from generic e-commerce examples

How to use this: - Each chapter maps to Odibi features (generators, transformers, patterns) - Beginner-friendly explanations assume you've forgotten most of your ChemE classes - YAML examples show how equations become data pipelines - LinkedIn-worthy content that proves you understand both ChemE AND data engineering


Quick Reference: Textbook Concepts → Odibi Features

Textbook Topic Odibi Feature Use Case
First-order systems (τ, K) prev() stateful function Tank level/temperature dynamics
Second-order systems (ζ, ωn) prev() + derived columns Underdamped responses, overshoot
PID control pid() transformer Temperature/pressure/level control
Time delays (θ) random_walk with lag Analyzer delays, dead time
Step/ramp inputs range, categorical Setpoint changes, disturbances
PRBS signals random_walk with constraints System identification tests
Measurement noise range (small) on sensors Realistic transmitter data
Process nonlinearity derived with conditional logic Gain scheduling scenarios
ARX/ARMAX models prev() + weighted sums Discrete-time identification
Transfer functions Combine prev(), ema(), pid(), delay() Full closed-loop simulations

Part I: Introduction to Process Control

Chapter 1: Introduction to Process Control

What you forgot from school: - Controlled Variable (CV): What you want to control (temperature, level, composition) - Manipulated Variable (MV): What you adjust to control it (valve position, heater power) - Disturbance Variable (DV): What messes things up (feed composition changes, ambient temperature)

Why this matters for data: You need realistic CV/MV/DV relationships to build convincing demos. A tank level that doesn't respond to inlet flow changes is obviously fake.

Odibi Implementation:

# Simple mixing tank: CV = outlet composition, MV = acid flow, DV = feed composition
simulation:
  entities: ["tank_001"]
  start_time: "2024-01-01 00:00:00"
  timestep: "1min"
  row_count: 1440  # 1 day
  seed: 42

  columns:
    # Disturbance: Feed composition varying naturally
    - name: feed_composition_pct
      data_type: float
      generator:
        type: random_walk
        start: 5.0
        min: 4.0
        max: 6.0
        step_size: 0.1

    # Manipulated Variable: Operator adjusting acid flow
    - name: acid_flow_gpm
      data_type: float
      generator:
        type: random_walk
        start: 10.0
        min: 5.0
        max: 15.0
        step_size: 0.5

    # Controlled Variable: Tank composition (mass balance)
    - name: tank_composition_pct
      data_type: float
      generator:
        type: derived
        expression: |
          # Simple mass balance (assuming perfect mixing)
          prev('tank_composition_pct', 5.0) +
          0.1 * (feed_composition_pct - prev('tank_composition_pct', 5.0)) +
          0.05 * (acid_flow_gpm - 10.0)

LinkedIn Post Idea: "🎯 ChemE 101: Building a mixing tank simulator from scratch. Notice how the CV lags the MV - that's first-order dynamics in action. No Aspen needed, just data pipelines."


Chapter 2: Theoretical Models of Chemical Processes

What you forgot: - Degrees of Freedom (DoF): DoF = Number of Variables − Number of Equations - If DoF > 0, you need to specify inputs - If DoF = 0, the system is fully determined (steady-state) - If DoF < 0, you over-specified (inconsistent equations)

Why this matters for data: When simulating, you must decide which variables are "given" (inputs) vs "calculated" (outputs). Getting DoF wrong means your simulation either crashes or produces garbage.

Odibi Implementation Pattern:

For a CSTR (Continuous Stirred Tank Reactor): - Variables: T (temperature), C (concentration), F (flow), V (volume), Q (heat input) - Equations: Mass balance, energy balance - DoF analysis: 5 variables − 2 equations = 3 DoF → specify 3 inputs (F, Q, inlet T or C)

columns:
  # Given inputs (3 DoF)
  - name: feed_flow_gpm
    data_type: float
    generator:
      type: constant
      value: 100.0

  - name: feed_temp_f
    data_type: float
    generator:
      type: random_walk
      start: 70.0
      min: 65.0
      max: 75.0
      step_size: 0.5

  - name: heat_input_mbtu_hr
    data_type: float
    generator:
      type: range
      min: 5.0
      max: 15.0

  # Calculated from mass/energy balance (0 DoF remaining)
  - name: reactor_temp_f
    data_type: float
    generator:
      type: derived
      expression: |
        # Simplified energy balance (first-order approximation)
        tau = 10.0  # minutes (residence time = V/F)
        prev_temp = prev('reactor_temp_f', 70.0)
        prev_temp + (1.0/tau) * (feed_temp_f - prev_temp + 0.5*heat_input_mbtu_hr)

Key Takeaway: Always count your DoF before building a simulation. If you try to "derive" all variables, Odibi will complain about circular dependencies.


Part II: Dynamic Behavior of Processes

Chapter 4: Transfer Function Models

What you forgot: A transfer function relates output to input in the Laplace domain:

G(s) = Y(s) / U(s)

The most common form in process control is First-Order Plus Time Delay (FOPTD):

G(s) = K e^(-θs) / (τs + 1)

Where: - K = process gain (steady-state output change per unit input change) - τ = time constant (how fast it responds - larger τ = slower) - θ = time delay (dead time before any response starts)

Why this matters for data: Almost every process unit (tank, heat exchanger, reactor) can be approximated as FOPTD. If you can simulate FOPTD, you can simulate 80% of real plant behavior.

Odibi Implementation:

# FOPTD: Tank temperature responding to heater power
# K = 2.0 °F/%, τ = 5 min, θ = 1 min

columns:
  # Input: Heater power (step change at t=10)
  - name: heater_pct
    data_type: float
    generator:
      type: derived
      expression: "50.0 if timestamp < timestamp.shift(10, 'min') else 60.0"

  # Delayed input (θ = 1 min)
  - name: heater_delayed
    data_type: float
    generator:
      type: derived
      expression: "prev('heater_pct', 50.0)"

  # Output: Temperature with first-order lag
  - name: tank_temp_f
    data_type: float
    generator:
      type: derived
      expression: |
        # Discrete approximation: y[k] = y[k-1] + (Δt/τ)(K*u[k] - y[k-1])
        K = 2.0
        tau = 5.0
        dt = 1.0  # minutes
        u = heater_delayed - 50.0  # deviation variable
        y_prev = prev('tank_temp_f', 100.0) - 100.0  # deviation from initial
        y_new = y_prev + (dt/tau) * (K*u - y_prev)
        100.0 + y_new  # convert back to absolute

Validation: For a 10% step in heater: - Initial temp: 100°F - Final temp: 100 + K×10 = 120°F - Time to 63.2%: τ = 5 min - Actual response starts at t = θ = 1 min

LinkedIn Post Idea: "📈 Every tank in your plant is secretly a transfer function. Here's how to simulate FOPTD in data pipelines - K, τ, and θ explained with zero Laplace math."


Chapter 5: Dynamic Behavior of First-Order and Second-Order Processes

First-Order Systems: The Building Block

What you forgot: The step response of a first-order system is:

y(t) = K(1 - e^(-t/τ))    (for unit step from zero)

Key metrics: - Time constant (τ): Time to reach 63.2% of final value - Settling time: ≈ 4τ (to reach 98% of final value) - Rise time: ≈ 2.2τ (10% to 90%)

Odibi Implementation:

# Generate step responses for different time constants
simulation:
  entities: ["slow_tank", "medium_tank", "fast_tank"]
  start_time: "2024-01-01 00:00:00"
  timestep: "10sec"
  row_count: 360  # 1 hour
  seed: 42

  columns:
    # Step input at t=5min
    - name: input_step
      data_type: float
      generator:
        type: derived
        expression: "0.0 if timestamp < timestamp.shift(5, 'min') else 1.0"

    # Slow response (τ = 10 min)
    - name: slow_response
      data_type: float
      generator:
        type: derived
        expression: |
          K = 2.0
          tau = 10.0  # minutes
          dt = 10.0/60.0  # 10 seconds in minutes
          u = input_step
          y_prev = prev('slow_response', 0.0)
          y_prev + (dt/tau) * (K*u - y_prev)

    # Fast response (τ = 1 min)
    - name: fast_response
      data_type: float
      generator:
        type: derived
        expression: |
          K = 2.0
          tau = 1.0
          dt = 10.0/60.0
          u = input_step
          y_prev = prev('fast_response', 0.0)
          y_prev + (dt/tau) * (K*u - y_prev)

Validation Test:

# After running simulation, check metrics
df = pipeline.run()

# Find settling time (time to reach 98% of final value)
final_value = df['slow_response'].iloc[-1]
threshold = 0.98 * final_value
settling_idx = df[df['slow_response'] >= threshold].index[0]
settling_time = (settling_idx - step_idx) * 10/60  # in minutes

assert abs(settling_time - 4*10) < 1.0  # Should be ~40 min (4τ)

Second-Order Systems: Overshoot and Oscillation

What you forgot: Second-order systems are described by:

G(s) = ωn² / (s² + 2ζωn·s + ωn²)

Where: - ωn = natural frequency (rad/time) - ζ = damping ratio: - ζ > 1: overdamped (slow, no overshoot) - ζ = 1: critically damped (fastest without overshoot) - 0 < ζ < 1: underdamped (fast, with overshoot) - ζ = 0: undamped (pure oscillation)

Key metrics for underdamped (ζ < 1): - Overshoot: Mp ≈ exp(-πζ / √(1-ζ²)) - Peak time: tp ≈ π / (ωn√(1-ζ²)) - Settling time: ts ≈ 4 / (ζωn)

Odibi Implementation:

# U-tube manometer or pressure gauge with damping
columns:
  # Step pressure change
  - name: pressure_step_psi
    data_type: float
    generator:
      type: derived
      expression: "0.0 if timestamp < timestamp.shift(2, 'min') else 10.0"

  # Second-order response (ζ = 0.3, ωn = 1.0 rad/min)
  # Using state-space: dx1/dt = x2, dx2/dt = -ωn²x1 - 2ζωn·x2 + ωn²u
  - name: velocity
    data_type: float
    generator:
      type: derived
      expression: |
        zeta = 0.3
        wn = 1.0
        dt = 10.0/60.0  # 10 seconds in minutes
        u = pressure_step_psi
        x1 = prev('pressure_reading_psi', 0.0)
        x2 = prev('velocity', 0.0)
        x2 + dt * (-wn*wn*x1 - 2*zeta*wn*x2 + wn*wn*u)

  - name: pressure_reading_psi
    data_type: float
    generator:
      type: derived
      expression: |
        dt = 10.0/60.0
        x2 = velocity
        prev('pressure_reading_psi', 0.0) + dt * x2

Expected behavior: - Input: 10 psi step - Overshoot: ≈ exp(-π×0.3/√(1-0.3²)) ≈ 37% - Peak: 10 × 1.37 = 13.7 psi at tp ≈ 3.3 min - Settles to 10 psi after ≈ 13 min

LinkedIn Post Idea: "🎢 Second-order systems explained: Why your pressure gauge overshoots and oscillates. Here's the damping ratio (ζ) cheatsheet every ChemE should remember."


Chapter 7: Development of Empirical Models from Process Data

What you forgot: You don't always have a physics model. Instead, you: 1. Apply test signals (steps, PRBS) 2. Collect input/output data 3. Fit an empirical model (FOPTD, ARX, ARMAX) 4. Validate with cross-validation

ARX Model (AutoRegressive with eXogenous input):

y[k] = a₁y[k-1] + a₂y[k-2] + ... + b₁u[k-1] + b₂u[k-2] + ... + e[k]

Why this matters: This is how real plant identification works. You can simulate "true" plant data, add noise, then test if your ID method recovers the parameters.

Odibi Implementation:

# Generate FOPTD data, then fit ARX to it
simulation:
  entities: ["tank_001"]
  start_time: "2024-01-01 00:00:00"
  timestep: "1min"
  row_count: 1440
  seed: 42

  columns:
    # PRBS input for persistent excitation
    - name: input_prbs
      data_type: float
      generator:
        type: random_walk
        start: 0.0
        min: -1.0
        max: 1.0
        step_size: 0.5

    # True FOPTD response (K=2, τ=5, θ=1)
    - name: output_true
      data_type: float
      generator:
        type: derived
        expression: |
          K = 2.0
          tau = 5.0
          dt = 1.0
          u = prev('input_prbs', 0.0)  # 1-min delay
          y_prev = prev('output_true', 0.0)
          y_prev + (dt/tau) * (K*u - y_prev)

    # Measured output (with noise)
    - name: output_measured
      data_type: float
      generator:
        type: derived
        expression: "output_true + noise"

    - name: noise
      data_type: float
      generator:
        type: range
        min: -0.1
        max: 0.1

# After simulation, fit ARX in Python:
# from statsmodels.tsa.arima.model import ARIMA
# model = ARIMA(output_measured, exog=input_prbs, order=(1,0,0))
# fitted = model.fit()
# print(fitted.params)  # Should recover a1 ≈ exp(-dt/tau) ≈ 0.82, b1 ≈ K(1-a1) ≈ 0.36

Validation: Compare one-step-ahead predictions vs actual. If RMSE is close to noise level (0.1), the model is good.


Part III: Feedback and Feedforward Control

Chapter 8: Feedback Controllers (PID)

What you forgot: The PID controller is the workhorse of process control:

u(t) = Kc[e(t) + (1/τI)∫e dt + τD(de/dt)]

Where: - Kc = proportional gain (how aggressive) - τI = integral time (eliminates offset) - τD = derivative time (anticipates changes, fights noise) - e(t) = error = setpoint − measurement

Odibi has a built-in pid() transformer!

Implementation:

# Tank level control with PID
columns:
  # Setpoint: Target level
  - name: level_setpoint_ft
    data_type: float
    generator:
      type: derived
      expression: "10.0 if timestamp < timestamp.shift(30, 'min') else 12.0"

  # Process variable: Tank level (integrating process)
  - name: level_pv_ft
    data_type: float
    generator:
      type: derived
      expression: |
        # Integrating process: dL/dt = (inflow - outflow) / Area
        area = 100.0  # ft²
        outflow = 50.0  # gpm (constant)
        inflow = valve_position  # gpm
        dt = 1.0  # minutes
        dL = (inflow - outflow) / area * 7.48  # gpm to ft³/min
        prev('level_pv_ft', 10.0) + dt * dL

  # Controller output: Inlet valve position
  - name: valve_position
    data_type: float
    generator:
      type: derived
      expression: |
        pid(
          pv='level_pv_ft',
          sp='level_setpoint_ft',
          Kp=5.0,
          Ki=0.1,
          Kd=0.0,
          dt=1.0,
          output_min=0.0,
          output_max=100.0
        )

Expected behavior: - P-only (Ki=0): offset remains (level settles below setpoint) - PI (Kd=0): offset eliminated, some overshoot - PID: faster response, derivative fights overshoot (but amplifies noise)

Tuning cheatsheet: - Too much Kc: oscillation - Too little Kc: slow response - Too much Ki: overshoot/oscillation - Too little Ki: slow offset elimination - Too much Kd: noise amplification - Too little Kd: sluggish on setpoint changes

LinkedIn Post Idea: "🎮 PID control demystified: The 3 knobs every plant engineer adjusts. Here's what they actually do, with live simulation data."


Chapter 12: PID Controller Tuning

What you forgot: There are many tuning methods. The most common:

1. Ziegler-Nichols (Ultimate Gain Method): - Increase Kc until sustained oscillation - Record Ku (ultimate gain) and Pu (period) - Use tuning rules: - P: Kc = 0.5Ku - PI: Kc = 0.45Ku, τI = Pu/1.2 - PID: Kc = 0.6Ku, τI = Pu/2, τD = Pu/8

2. Direct Synthesis / IMC: - Fit FOPTD model (K, τ, θ) - Choose closed-loop time constant λ (tuning parameter) - PI tuning: Kc = τ/(K(λ+θ)), τI = τ

Odibi Implementation:

# Step 1: Open-loop step test to get K, τ, θ
simulation:
  columns:
    - name: input_step
      data_type: float
      generator:
        type: derived
        expression: "0.0 if timestamp < timestamp.shift(5, 'min') else 1.0"

    - name: output_response
      data_type: float
      generator:
        type: derived
        expression: |
          # Your actual process
          K = 2.0
          tau = 10.0
          theta = 2.0
          dt = 1.0
          u = prev('input_step', 0.0, lag=int(theta))  # delay
          y_prev = prev('output_response', 0.0)
          y_prev + (dt/tau) * (K*u - y_prev)

# Step 2: Fit K, τ, θ from step response
# (Use curve_fit or graphical method: K = Δy/Δu, τ from 63.2% time, θ from start)

# Step 3: Calculate IMC tuning
# λ = tau  # aggressive
# Kc = tau / (K * (lambda + theta)) = 10 / (2 * (10 + 2)) = 0.42
# Ti = tau = 10

# Step 4: Implement PID with calculated tuning
columns:
  - name: controller_output
    data_type: float
    generator:
      type: derived
      expression: |
        pid(
          pv='output_response',
          sp='setpoint',
          Kp=0.42,
          Ki=0.042,  # Kp/Ti
          Kd=0.0,
          dt=1.0,
          output_min=0.0,
          output_max=10.0
        )

Validation: Compare tuning methods (ZN vs IMC vs manual) by running same disturbance/setpoint changes and measuring: - IAE (Integral Absolute Error) - ISE (Integral Square Error) - Overshoot % - Settling time


Chapter 15: Feedforward and Ratio Control

What you forgot: - Feedback (PID): Reacts to errors after they happen (slow) - Feedforward: Anticipates disturbances before they affect the process (fast)

Example: Distillation column - Disturbance: feed flow rate changes - Feedback: measure top composition, adjust reflux (slow, 5-10 min lag) - Feedforward: measure feed flow, immediately adjust reflux proportionally (instant)

Ideal feedforward:

Gff(s) = -Gd(s) / Gp(s)

Where: - Gd = disturbance-to-output transfer function - Gp = manipulated-to-output transfer function

Odibi Implementation:

# Ratio control: Maintain fixed ratio of two flows
columns:
  # Disturbance: Primary flow (wild)
  - name: feed_flow_gpm
    data_type: float
    generator:
      type: random_walk
      start: 100.0
      min: 80.0
      max: 120.0
      step_size: 2.0

  # Feedforward: Adjust secondary flow to maintain ratio
  - name: additive_flow_setpoint_gpm
    data_type: float
    generator:
      type: derived
      expression: "feed_flow_gpm * 0.15"  # 15% ratio

  # Actual secondary flow (with PI trim)
  - name: additive_flow_pv_gpm
    data_type: float
    generator:
      type: derived
      expression: |
        pid(
          pv='additive_flow_pv_gpm',
          sp='additive_flow_setpoint_gpm',
          Kp=0.5,
          Ki=0.05,
          Kd=0.0,
          dt=1.0,
          output_min=0.0,
          output_max=50.0
        )

Key point: Feedforward eliminates 80-90% of disturbance immediately. Feedback (PI trim) handles model mismatch and unmeasured disturbances.


Part IV: Advanced Process Control

Chapter 16: Enhanced Single-Loop Control Strategies

Cascade Control: Fast Inner Loop, Slow Outer Loop

What you forgot: Use cascade when: - Secondary (fast) measurement is available - Disturbances affect the intermediate variable - Inner loop can reject disturbances before they affect outer loop

Example: Reactor temperature control - Primary (outer): reactor temperature (slow, 10 min) - Secondary (inner): jacket temperature (fast, 1 min) - Disturbance: jacket inlet temperature varies

Odibi Implementation:

columns:
  # Primary setpoint: Desired reactor temperature
  - name: reactor_temp_sp_f
    data_type: float
    generator:
      type: constant
      value: 180.0

  # Primary PID: Reactor temperature → Jacket setpoint
  - name: jacket_temp_sp_f
    data_type: float
    generator:
      type: derived
      expression: |
        pid(
          pv='reactor_temp_pv_f',
          sp='reactor_temp_sp_f',
          Kp=2.0,
          Ki=0.1,
          Kd=0.0,
          dt=1.0,
          output_min=100.0,
          output_max=200.0
        )

  # Secondary PID: Jacket temperature → Valve position
  - name: steam_valve_pct
    data_type: float
    generator:
      type: derived
      expression: |
        pid(
          pv='jacket_temp_pv_f',
          sp='jacket_temp_sp_f',
          Kp=5.0,
          Ki=0.5,
          Kd=0.0,
          dt=1.0,
          output_min=0.0,
          output_max=100.0
        )

  # Fast process: Jacket temperature
  - name: jacket_temp_pv_f
    data_type: float
    generator:
      type: derived
      expression: |
        # First-order, fast (τ = 1 min)
        K = 1.0
        tau = 1.0
        dt = 1.0
        u = steam_valve_pct
        y_prev = prev('jacket_temp_pv_f', 120.0)
        y_prev + (dt/tau) * (K*u + 100.0 - y_prev)

  # Slow process: Reactor temperature
  - name: reactor_temp_pv_f
    data_type: float
    generator:
      type: derived
      expression: |
        # First-order, slow (τ = 10 min)
        K = 0.5
        tau = 10.0
        dt = 1.0
        u = jacket_temp_pv_f - 150.0  # deviation
        y_prev = prev('reactor_temp_pv_f', 170.0)
        y_prev + (dt/tau) * (K*u - (y_prev - 170.0))

Tuning rule: Tune inner loop first (aggressive), then outer loop (slower).


Chapter 20: Model Predictive Control (MPC)

What you forgot: MPC is the "fancy" controller that: - Predicts future behavior using a model - Handles constraints explicitly (min/max on MVs and CVs) - Optimizes a cost function over a future horizon - Used in refineries, polymerization, power plants

Basic idea:

min J = Σ ||ŷ - r||² + Σ ||Δu||²
subject to: umin ≤ u ≤ umax, ymin ≤ y ≤ ymax

Why this matters: You can simulate MPC-controlled processes to show constraint handling and optimal steady-state.

Odibi Implementation (Simplified MPC-like logic):

# Constrained level control: Keep level between 8-12 ft, minimize flow changes
columns:
  - name: level_setpoint_ft
    data_type: float
    generator:
      type: constant
      value: 10.0

  - name: level_pv_ft
    data_type: float
    generator:
      type: derived
      expression: |
        # Integrating process
        area = 100.0
        inflow = valve_position
        outflow = 50.0
        dt = 1.0
        dL = (inflow - outflow) / area * 7.48
        clamp(prev('level_pv_ft', 10.0) + dt * dL, 0.0, 15.0)

  # MPC-like controller (simplified: PID with move suppression)
  - name: valve_position
    data_type: float
    generator:
      type: derived
      expression: |
        # PID with rate-of-change penalty (move suppression)
        error = level_setpoint_ft - level_pv_ft
        integral = prev('integral', 0.0) + error
        derivative = error - prev('error', 0.0)

        Kp = 3.0
        Ki = 0.05
        Kd = 0.0
        move_penalty = 0.1

        # Raw PID
        u_raw = Kp*error + Ki*integral + Kd*derivative

        # Constrain move size (MPC move suppression)
        u_prev = prev('valve_position', 50.0)
        delta_max = 5.0  # max 5 gpm change per minute
        u_constrained = clamp(u_raw, u_prev - delta_max, u_prev + delta_max)

        # Constrain output
        clamp(u_constrained, 0.0, 100.0)

  - name: error
    data_type: float
    generator:
      type: derived
      expression: "level_setpoint_ft - level_pv_ft"

  - name: integral
    data_type: float
    generator:
      type: derived
      expression: "prev('integral', 0.0) + error"

Key difference from PID: MPC explicitly limits rate-of-change (Δu) to avoid aggressive valve movements. PID only limits output magnitude.


Practical Simulation Recipes

Recipe 1: Full Closed-Loop Temperature Control

Scenario: Tank with heating coil, ambient losses, PID controller

simulation:
  entities: ["tank_TK101"]
  start_time: "2024-01-01 00:00:00"
  timestep: "1min"
  row_count: 480  # 8 hours
  seed: 42

  columns:
    # Setpoint schedule
    - name: temp_setpoint_f
      data_type: float
      generator:
        type: derived
        expression: |
          if timestamp.hour < 2:
              150.0
          elif timestamp.hour < 4:
              180.0
          else:
              160.0

    # Disturbance: Ambient temperature
    - name: ambient_temp_f
      data_type: float
      generator:
        type: random_walk
        start: 70.0
        min: 65.0
        max: 75.0
        step_size: 0.5

    # Controller
    - name: heater_output_pct
      data_type: float
      generator:
        type: derived
        expression: |
          pid(
            pv='tank_temp_pv_f',
            sp='temp_setpoint_f',
            Kp=2.0,
            Ki=0.1,
            Kd=0.5,
            dt=1.0,
            output_min=0.0,
            output_max=100.0
          )

    # Process: Energy balance
    - name: tank_temp_pv_f
      data_type: float
      generator:
        type: derived
        expression: |
          # dT/dt = (Q_heater - Q_loss) / (m*cp)
          m_cp = 1000.0  # thermal mass (BTU/°F)
          UA = 50.0  # heat loss coefficient (BTU/min/°F)
          Q_max = 500.0  # max heater power (BTU/min)

          T_prev = prev('tank_temp_pv_f', 150.0)
          Q_heater = heater_output_pct / 100.0 * Q_max
          Q_loss = UA * (T_prev - ambient_temp_f)

          dt = 1.0
          dT = (Q_heater - Q_loss) / m_cp
          T_prev + dt * dT

    # Sensor noise
    - name: temp_sensor_noise_f
      data_type: float
      generator:
        type: range
        min: -0.5
        max: 0.5

    - name: tank_temp_measured_f
      data_type: float
      generator:
        type: derived
        expression: "tank_temp_pv_f + temp_sensor_noise_f"

What this demonstrates: - Setpoint tracking - Disturbance rejection (ambient temperature) - Controller tuning trade-offs (Kp/Ki/Kd) - Sensor noise effects


Recipe 2: System Identification Test

Scenario: PRBS input test to identify unknown process

simulation:
  entities: ["mystery_process"]
  start_time: "2024-01-01 00:00:00"
  timestep: "30sec"
  row_count: 1200  # 10 hours
  seed: 42

  columns:
    # PRBS input (Pseudo-Random Binary Sequence)
    - name: input_prbs
      data_type: float
      generator:
        type: random
        distribution: choice
        choices: [-1.0, -0.5, 0.0, 0.5, 1.0]

    # True process (FOPTD with nonlinearity)
    - name: output_true
      data_type: float
      generator:
        type: derived
        expression: |
          # K varies with operating point (gain scheduling)
          u = prev('input_prbs', 0.0)
          if u > 0.5:
              K = 3.0  # high gain region
          else:
              K = 2.0  # low gain region

          tau = 5.0
          dt = 30.0/60.0  # 30 sec in minutes
          y_prev = prev('output_true', 0.0)
          y_prev + (dt/tau) * (K*u - y_prev)

    # Measurement with realistic noise
    - name: output_measured
      data_type: float
      generator:
        type: derived
        expression: "output_true + noise + bias_drift"

    - name: noise
      data_type: float
      generator:
        type: range
        min: -0.2
        max: 0.2

    - name: bias_drift
      data_type: float
      generator:
        type: random_walk
        start: 0.0
        min: -0.1
        max: 0.1
        step_size: 0.01

Analysis in Python:

# Fit ARX model
from statsmodels.tsa.arima.model import ARIMA

df = pipeline.run()
model = ARIMA(df['output_measured'], exog=df['input_prbs'], order=(2,0,1))
fitted = model.fit()

# Validate with cross-validation
train = df.iloc[:800]
test = df.iloc[800:]
# ... fit on train, predict on test, compute RMSE


Beginner Concepts Explained

What is "Lag" vs "Delay"?

Lag (τ): System takes time to respond because of physical capacity (thermal mass, tank volume) - Example: Tank temperature changes slowly because water has high heat capacity - Math: First-order differential equation

Delay (θ): Signal takes time to travel or process - Example: Composition analyzer sits 50 feet from reactor → 2-minute dead time - Math: Pure time shift

In Odibi:

# Lag: use prev() with exponential weighting
- name: lagged_value
  data_type: float
  generator:
    type: derived
    expression: "ema('raw_value', alpha=0.2, default=0.0)"

# Delay: use prev() with offset
- name: delayed_value
  data_type: float
  generator:
    type: derived
    expression: "prev('raw_value', default=0.0, lag=5)"  # 5 timesteps ago


What is "Overshoot"?

Overshoot: When a controlled variable exceeds the setpoint before settling

Causes: - High controller gain (Kc too large) - Underdamped second-order process (ζ < 1) - Large dead time (θ) relative to time constant (τ)

How to reduce: - Decrease Kc - Increase τI (slower integral) - Add derivative action (τD) - Use 2-degree-of-freedom PID (setpoint weighting)

In Odibi:

# Standard PID: 30% overshoot
- name: aggressive_control
  data_type: float
  generator:
    type: derived
    expression: "pid(pv='temp', sp='setpoint', Kp=5.0, Ki=0.5, Kd=0.0, dt=1.0)"

# Conservative PID: 5% overshoot
- name: conservative_control
  data_type: float
  generator:
    type: derived
    expression: "pid(pv='temp', sp='setpoint', Kp=2.0, Ki=0.1, Kd=0.5, dt=1.0)"


What is "Integral Windup"?

Problem: When MV is saturated (0% or 100%), error keeps accumulating in integral term → huge overshoot when constraint releases

Example: 1. Setpoint jumps from 100°F to 200°F 2. Heater goes to 100% (saturated) 3. Error is still 50°F, so integral keeps growing 4. When temperature reaches 200°F, integral is huge 5. Heater stays at 100% way too long → overshoot to 220°F

Solution: Anti-windup (stop integrating when saturated)

Odibi's pid() has built-in anti-windup!

- name: safe_control
  data_type: float
  generator:
    type: derived
    expression: |
      pid(
        pv='level',
        sp='setpoint',
        Kp=3.0,
        Ki=0.2,
        Kd=0.0,
        dt=1.0,
        output_min=0.0,    # Anti-windup kicks in here
        output_max=100.0   # and here
      )

LinkedIn Content Series Outline

Post Series: "ChemE × Data Engineering"

Post 1: The Missing Link "Why are all data demos about e-commerce? Let me show you process control simulation with real ChemE concepts. Starting with: What is a transfer function, really?" - Show FOPTD tank simulation - Link to this guide

Post 2: First-Order Systems "Every tank in your plant is secretly a first-order system. Here's how to simulate realistic level, temperature, and flow data." - K, τ, θ explained with visuals - YAML example - Validation metrics

Post 3: PID Control Demystified "The 3 knobs every plant engineer adjusts: Proportional, Integral, Derivative. Here's what they actually do." - PID simulation - Tuning trade-offs - Overshoot examples

Post 4: Why Your Controller Oscillates "Spoiler: It's either too much gain or too much dead time. Here's how to diagnose with simulated data." - Stability examples - Ziegler-Nichols gone wrong - Bode plots

Post 5: System Identification "You don't have a model? No problem. Here's how to recover transfer functions from PRBS test data." - ARX fitting - Cross-validation - Model mismatch

Post 6: Cascade Control "When one loop isn't enough: Fast inner loop + slow outer loop = disturbance rejection magic." - Reactor temperature example - Performance comparison

Post 7: Feedforward: The Secret Weapon "Feedback is reactive. Feedforward is proactive. Here's how to anticipate disturbances before they hit your process." - Ratio control - FF+FB combination

Post 8: MPC for the Masses "Model Predictive Control isn't just for refineries anymore. Here's a simplified version you can actually understand." - Constraint handling - Move suppression - Cost function trade-offs


Appendix: Odibi Feature → Textbook Concept Mapping

Odibi Feature Textbook Concept Chapter
prev() Euler integration, discrete-time models 4, 5, 17
ema() First-order filter, sensor smoothing 5, 9
pid() PID controller (parallel form) 8, 12
random_walk PRBS, disturbances, sensor drift 7, 21
range Measurement noise, uncertainties 9
derived State-space equations, ODEs 2, 4
constant Equipment parameters, setpoints 2
categorical Mode/grade changes, discrete states 22
Simulation seed Reproducibility for experiments 7
Incremental loading Online data collection, streaming 17

Next Steps

  1. Pick a chapter from the outline above
  2. Build the simulation using Odibi YAML
  3. Validate against textbook equations/plots
  4. Write a LinkedIn post showing your unique ChemE+DE skills
  5. Repeat for 8-12 chapters → you now have a portfolio

Remember: - Start simple (FOPTD, single-loop PID) - Add complexity gradually (cascade, MIMO, MPC) - Always validate against theory - Show your work on LinkedIn


Questions? Found an error? Open an issue or PR: github.com/henryodibi11/Odibi

Want more? - Process Simulation Guide - Deep dive on stateful functions - Chemical Engineering Simulation Guide - Advanced topics - Thermodynamics Transformers - Steam tables, psychrometrics - Reference: Simulation Generators - All generators explained